Automatic Transmission System Precaution Manual for Toyota Supra

toyota supra automatic transmission  Automatic Transmission System Precaution Manual for Toyota Supra

EXTENSION HOUSING OIL SEAL
ON–VEHICLE REPAIR
1. REMOVE DRAIN PLUG AND DRAIN ATF
2. REMOVE FRONT EXHAUST PIPE AND HEAT INSULATOR
(See page EM–94)
3. REMOVE PROPELLER SHAFT (See page PR–5)
4. REMOVE TRANSMISSION OUTPUT FLANGE
(a) Using a chisel and hammer, loosen the staked part of the
nut.
HINT:
Shift the shift lever to the P position.
(b) Remove the nut.
(c) Tap the output flange with a plastic hammer to remove it
and 2 washers.
(d) Using a screwdriver, remove the oil seal from the output
flange.
5. REMOVE EXTENSION HOUSING REAR OIL SEAL
Using SST, remove the oil seal.
SST 09308–00010
6. INSTALL EXTENSION HOUSING REAR OIL SEAL
(a) Coat the lip of a new oil seal with MP grease.

Category : Automotive, Toyota
Source : http://www.supralife.ru
Language : English
View : 1,534 views
Size : 400 kb
Date : March 24th, 2010
Vote This Post DownVote This Post Up (No Ratings Yet)
Loading ... Loading ...

student loan consolidation
 
Popular Rated


Copyright © 2009 PDFArena.com. All rights reserved.


If you see unrelated pdf files with the description or copyrighted material published, please report to us, we'll correct/delete it it as soon as possible.NONE OF THOSE MATERIALS ARE HOSTED IN THIS SERVER NOR UPLOADED BY ME IN SOMEONE'S SERVERS.  Read our Disclaimer for more detail.

We are neither affiliated with authors and brands nor responsible for its content and change of content.

Information contained herein is provided "as is" without warranty of any kind, either expressed or implied, including any warranty of merchantability or fitness for a particular purpose. In no event shall ANYONE be held liable for any loss of profit, special, incidental, consequential, or other similar claims.
Books blogs & blog posts My Zimbio On our way to 1,000,000 rss feeds - millionrss.com